Miniature Circuit Breakers B16
Miniature circuit breakers B16 are among the most commonly used circuit breakers in electrical installations. With a rated current of 16 amperes and B characteristic, they are ideal for circuits with low inrush currents, as typically found in residential buildings.
Here you will find Siemens miniature circuit breakers B16 in various pole configurations for professional installations.
Siemens 5SY4116-6 CC - Miniature Circuit Breaker 1-pole B16A 10kA
Number of poles: 1-poleTripping characteristic: BRated current: 16ARated voltage: 230/400VBreaking capacity (EN 60898): 10kAThe Siemens miniature circuit breaker 5SY4116-6 reliably protects electrical circuits against overload and short circuit – 1-pole, tripping characteristic B, 16A at 230/400V and 10kA breaking capacity (EN 60898). Suitable for residential, commercial and industrial applications.
Siemens 5SY4316-6 CC - Miniature Circuit Breaker 3-pole B16A 10kA
Number of poles: 3-poleTripping characteristic: BRated current: 16ARated voltage: 400VBreaking capacity (EN 60898): 10kAThe Siemens miniature circuit breaker 5SY4316-6 reliably protects electrical circuits against overload and short circuit – 3-pole, tripping characteristic B, 16A at 400V and 10kA breaking capacity (EN 60898). Suitable for residential, commercial and industrial applications.
What is a miniature circuit breaker B16?
A miniature circuit breaker B16 is a circuit breaker with 16 A rated current and B characteristic.
In the event of a short circuit it trips at about 3 to 5 times the rated current and reliably protects electrical cables against overload and short circuit.
B16 miniature circuit breakers are used primarily in classic household circuits and comply with the standard DIN EN 60898-1.
Typical areas of application for B16 miniature circuit breakers
Miniature circuit breakers with B16 characteristic are used particularly often in:
-
Socket circuits
-
Lighting circuits
-
Residential installations
-
Office and administrative buildings
-
Standard loads without high inrush currents
Difference between B16 and C16
The choice between B16 and C16 depends on the inrush current of the connected loads:
-
B16
For circuits with low inrush currents, e.g. lighting, sockets, household appliances -
C16
For circuits with increased inrush current, e.g. motors, power supplies, machines
In residential buildings, B16 is generally used.
Which numbers of poles are available for C16?
Miniature circuit breakers B16 are available in various versions, including:
-
1-pole Miniature Circuit Breakers B16
-
1P+N Miniature Circuit Breakers B16
-
2-pole Miniature Circuit Breakers B16
-
3-pole Miniature Circuit Breakers B16
-
3P+N Miniature Circuit Breakers B16
This allows different system types and installation requirements to be covered.
Technical features of miniature circuit breakers C16
Typical properties of B16 MCBs are:
-
Rated current: 16 A
-
Tripping characteristic: B
-
Rated voltage: usually 230 / 400 V AC
-
Breaking capacity: 10 kA or 15 kA (depending on model)
-
Standard: DIN EN 60898-1
Frequently asked questions about miniature circuit breakers C16 (FAQ)
When should I use a miniature circuit breaker B16?
For standard circuits with low inrush current load, such as sockets or lighting.
Is B16 the standard in residential buildings?
Yes, B16 is the most commonly used characteristic in residential buildings.
Can I replace B16 with C16?
Only if the circuit is designed for it and higher inrush currents occur.
Which number of poles is the right one?
That depends on the system type and the application – various versions are available from 1-pole to 3P+N.