1-pole Miniature Circuit Breakers Characteristic B
1-pole miniature circuit breakers with characteristic B are used predominantly in residential buildings and classic installations. They trip at 3 to 5 times the rated current and are particularly suitable for lighting and socket circuits with low inrush currents.
In this category you will find 1-pole Siemens miniature circuit breakers with characteristic B in various current ratings.
Siemens 5SY4116-6 CC - Miniature Circuit Breaker 1-pole B16A 10kA
Number of poles: 1-poleTripping characteristic: BRated current: 16ARated voltage: 230/400VBreaking capacity (EN 60898): 10kAThe Siemens miniature circuit breaker 5SY4116-6 reliably protects electrical circuits against overload and short circuit – 1-pole, tripping characteristic B, 16A at 230/400V and 10kA breaking capacity (EN 60898). Suitable for residential, commercial and industrial applications.
Siemens 5SY4110-6 CC - Miniature Circuit Breaker 1-pole B10A 10kA
Number of poles: 1-poleTripping characteristic: BRated current: 10ARated voltage: 230/400VBreaking capacity (EN 60898): 10kAThe Siemens miniature circuit breaker 5SY4110-6 reliably protects electrical circuits against overload and short circuit – 1-pole, tripping characteristic B, 10A at 230/400V and 10kA breaking capacity (EN 60898). Suitable for residential, commercial and industrial applications.
Siemens 5SY4120-6 CC - Miniature Circuit Breaker 1-pole B20A 10kA
Number of poles: 1-poleTripping characteristic: BRated current: 20ARated voltage: 230/400VBreaking capacity (EN 60898): 10kAThe Siemens miniature circuit breaker 5SY4120-6 reliably protects electrical circuits against overload and short circuit – 1-pole, tripping characteristic B, 20A at 230/400V and 10kA breaking capacity (EN 60898). Suitable for residential, commercial and industrial applications.
Siemens 5SY4102-6 CC - Miniature Circuit Breaker 1-pole B2A 10kA
Number of poles: 1-poleTripping characteristic: BRated current: 2ARated voltage: 230/400VBreaking capacity (EN 60898): 10kAThe Siemens miniature circuit breaker 5SY4102-6 reliably protects electrical circuits against overload and short circuit – 1-pole, tripping characteristic B, 2A at 230/400V and 10kA breaking capacity (EN 60898). Suitable for residential, commercial and industrial applications.
Siemens 5SY4125-6 CC - Miniature Circuit Breaker 1-pole B25A 10kA
Number of poles: 1-poleTripping characteristic: BRated current: 25ARated voltage: 230/400VBreaking capacity (EN 60898): 10kAThe Siemens miniature circuit breaker 5SY4125-6 reliably protects electrical circuits against overload and short circuit – 1-pole, tripping characteristic B, 25A at 230/400V and 10kA breaking capacity (EN 60898). Suitable for residential, commercial and industrial applications.
Siemens 5SY4132-6 CC - Miniature Circuit Breaker 1-pole B32A 10kA
Number of poles: 1-poleTripping characteristic: BRated current: 32ARated voltage: 230/400VBreaking capacity (EN 60898): 10kAThe Siemens miniature circuit breaker 5SY4132-6 reliably protects electrical circuits against overload and short circuit – 1-pole, tripping characteristic B, 32A at 230/400V and 10kA breaking capacity (EN 60898). Suitable for residential, commercial and industrial applications.
Siemens 5SY4150-6 CC - Miniature Circuit Breaker 1-pole B50A 10kA
Number of poles: 1-poleTripping characteristic: BRated current: 50ARated voltage: 230/400VBreaking capacity (EN 60898): 10kAThe Siemens miniature circuit breaker 5SY4150-6 reliably protects electrical circuits against overload and short circuit – 1-pole, tripping characteristic B, 50A at 230/400V and 10kA breaking capacity (EN 60898). Suitable for residential, commercial and industrial applications.
When is a 1-pole miniature circuit breaker with characteristic B used?
1-pole MCBs characteristic B are typically used in:
-
lighting circuits
-
socket circuits
-
residential buildings
-
smaller commercial installations
-
systems with low inrush currents
They are the standard in classic domestic installations.
Why characteristic B?
Characteristic B is designed for circuits with low inrush current peaks.
Magnetic tripping occurs at:
3–5 × In
This means:
-
fast disconnection in the event of a short circuit
-
high protection sensitivity
-
optimal for typical household loads
For motors or higher inrush currents, characteristic C is often used.
Available rated currents for 1-pole characteristic B
Typical current ratings are:
-
B10
-
B16
B10 is often used for lighting circuits.
B16 is the common standard for socket circuits in residential areas.
Difference between characteristic B, C and D
| Characteristic | Tripping | Typical use |
| B | 3–5 x In | Residential |
| C | 5–10 x In | Commercial |
| D | 10–20 x In | Industrial |
Characteristic B is the most sensitive version and therefore ideal for typical household applications.
Technical features and standards
1-pole miniature circuit breakers with characteristic B typically offer:
-
Thermal-magnetic tripping
-
Tripping curve 3–5 × In
-
DIN rail mounting
-
Compliance with DIN EN 60898-1
-
compact design for distribution boards
Installation must be carried out exclusively by a qualified electrician.
Frequently asked questions about 1-pole miniature circuit breakers characteristic B
When is B used instead of C?
When no high inrush currents occur, for example in lighting or socket circuits.
Is characteristic B suitable for motors?
As a rule, no. For motors, characteristic C or D is usually used.
Which current rating is the most common?
B16 is the most widespread in residential areas.