1-pole Miniature Circuit Breakers Characteristic C
1-pole miniature circuit breakers with characteristic C are used in single-phase circuits where increased inrush currents can occur. They trip at 5 to 10 times the rated current and provide reliable protection for commercial installations and technical loads with moderate starting currents.
In this category you will find 1-pole Siemens miniature circuit breakers with characteristic C in various current ratings.
Siemens 5SY4102-7 CV - Miniature Circuit Breaker 1-pole C2A 15kA
Number of poles: 1-poleTripping characteristic: CRated current: 2ARated voltage: 230/400VBreaking capacity (IEC 60947-2): 15kAThe Siemens miniature circuit breaker 5SY4102-7 reliably protects electrical circuits against overload and short circuit – 1-pole, tripping characteristic C, 2A at 230/400V and 15kA breaking capacity (IEC 60947-2). Suitable for residential, commercial and industrial applications.
Siemens 5SY4116-7 CV - Miniature Circuit Breaker 1-pole C16A 15kA
Number of poles: 1-poleTripping characteristic: CRated current: 16ARated voltage: 230/400VBreaking capacity (IEC 60947-2): 15kAThe Siemens miniature circuit breaker 5SY4116-7 reliably protects electrical circuits against overload and short circuit – 1-pole, tripping characteristic C, 16A at 230/400V and 15kA breaking capacity (IEC 60947-2). Suitable for residential, commercial and industrial applications.
Siemens 5SY4104-7 CV - Miniature Circuit Breaker 1-pole C4A 15kA
Number of poles: 1-poleTripping characteristic: CRated current: 4ARated voltage: 230/400VBreaking capacity (IEC 60947-2): 15kAThe Siemens miniature circuit breaker 5SY4104-7 reliably protects electrical circuits against overload and short circuit – 1-pole, tripping characteristic C, 4A at 230/400V and 15kA breaking capacity (IEC 60947-2). Suitable for residential, commercial and industrial applications.
Siemens 5SY4110-7 CV - Miniature Circuit Breaker 1-pole C10A 15kA
Number of poles: 1-poleTripping characteristic: CRated current: 10ARated voltage: 230/400VBreaking capacity (IEC 60947-2): 15kAThe Siemens miniature circuit breaker 5SY4110-7 reliably protects electrical circuits against overload and short circuit – 1-pole, tripping characteristic C, 10A at 230/400V and 15kA breaking capacity (IEC 60947-2). Suitable for residential, commercial and industrial applications.
Siemens 5SY4106-7 CV - Miniature Circuit Breaker 1-pole C6A 15kA
Number of poles: 1-poleTripping characteristic: CRated current: 6ARated voltage: 230/400VBreaking capacity (IEC 60947-2): 15kAThe Siemens miniature circuit breaker 5SY4106-7 reliably protects electrical circuits against overload and short circuit – 1-pole, tripping characteristic C, 6A at 230/400V and 15kA breaking capacity (IEC 60947-2). Suitable for residential, commercial and industrial applications.
Siemens 5SY4113-7 CV - Miniature Circuit Breaker 1-pole C13A 15kA
Number of poles: 1-poleTripping characteristic: CRated current: 13ARated voltage: 230/400VBreaking capacity (IEC 60947-2): 15kAThe Siemens miniature circuit breaker 5SY4113-7 reliably protects electrical circuits against overload and short circuit – 1-pole, tripping characteristic C, 13A at 230/400V and 15kA breaking capacity (IEC 60947-2). Suitable for residential, commercial and industrial applications.
Siemens 5SY4125-7 CV - Miniature Circuit Breaker 1-pole C25A 15kA
Number of poles: 1-poleTripping characteristic: CRated current: 25ARated voltage: 230/400VBreaking capacity (IEC 60947-2): 15kAThe Siemens miniature circuit breaker 5SY4125-7 reliably protects electrical circuits against overload and short circuit – 1-pole, tripping characteristic C, 25A at 230/400V and 15kA breaking capacity (IEC 60947-2). Suitable for residential, commercial and industrial applications.
Siemens 5SY4120-7 CV - Miniature Circuit Breaker 1-pole C20A 15kA
Number of poles: 1-poleTripping characteristic: CRated current: 20ARated voltage: 230/400VBreaking capacity (IEC 60947-2): 15kAThe Siemens miniature circuit breaker 5SY4120-7 reliably protects electrical circuits against overload and short circuit – 1-pole, tripping characteristic C, 20A at 230/400V and 15kA breaking capacity (IEC 60947-2). Suitable for residential, commercial and industrial applications.
Siemens 5SY4114-7 CV - Miniature Circuit Breaker 1-pole C0.3A 15kA
Number of poles: 1-poleTripping characteristic: CRated current: 0.3ARated voltage: 230/400VBreaking capacity (IEC 60947-2): 15kAThe Siemens miniature circuit breaker 5SY4114-7 reliably protects electrical circuits against overload and short circuit – 1-pole, tripping characteristic C, 0.3A at 230/400V and 15kA breaking capacity (IEC 60947-2). Suitable for residential, commercial and industrial applications.
Siemens 5SY4150-7 CV - Miniature Circuit Breaker 1-pole C50A 15kA
Number of poles: 1-poleTripping characteristic: CRated current: 50ARated voltage: 230/400VBreaking capacity (IEC 60947-2): 15kAThe Siemens miniature circuit breaker 5SY4150-7 reliably protects electrical circuits against overload and short circuit – 1-pole, tripping characteristic C, 50A at 230/400V and 15kA breaking capacity (IEC 60947-2). Suitable for residential, commercial and industrial applications.
Siemens 5SY4113-7 CC - Miniature Circuit Breaker 1-pole C13A 10kA
Number of poles: 1-poleTripping characteristic: CRated current: 13ARated voltage: 230/400VBreaking capacity (EN 60898): 10kAThe Siemens miniature circuit breaker 5SY4113-7 reliably protects electrical circuits against overload and short circuit – 1-pole, tripping characteristic C, 13A at 230/400V and 10kA breaking capacity (EN 60898). Suitable for residential, commercial and industrial applications.
Siemens 5SY4105-7 CV - Miniature Circuit Breaker 1-pole C0.5A 15kA
Number of poles: 1-poleTripping characteristic: CRated current: 0.5ARated voltage: 230/400VBreaking capacity (IEC 60947-2): 15kAThe Siemens miniature circuit breaker 5SY4105-7 reliably protects electrical circuits against overload and short circuit – 1-pole, tripping characteristic C, 0.5A at 230/400V and 15kA breaking capacity (IEC 60947-2). Suitable for residential, commercial and industrial applications.
Siemens 5SY4140-7 CV - Miniature Circuit Breaker 1-pole C40A 15kA
Number of poles: 1-poleTripping characteristic: CRated current: 40ARated voltage: 230/400VBreaking capacity (IEC 60947-2): 15kAThe Siemens miniature circuit breaker 5SY4140-7 reliably protects electrical circuits against overload and short circuit – 1-pole, tripping characteristic C, 40A at 230/400V and 15kA breaking capacity (IEC 60947-2). Suitable for residential, commercial and industrial applications.
Siemens 5SY4101-7 CV - Miniature Circuit Breaker 1-pole C1A 15kA
Number of poles: 1-poleTripping characteristic: CRated current: 1ARated voltage: 230/400VBreaking capacity (IEC 60947-2): 15kAThe Siemens miniature circuit breaker 5SY4101-7 reliably protects electrical circuits against overload and short circuit – 1-pole, tripping characteristic C, 1A at 230/400V and 15kA breaking capacity (IEC 60947-2). Suitable for residential, commercial and industrial applications.
Siemens 5SY4103-7 CV - Miniature Circuit Breaker 1-pole C3A 15kA
Number of poles: 1-poleTripping characteristic: CRated current: 3ARated voltage: 230/400VBreaking capacity (IEC 60947-2): 15kAThe Siemens miniature circuit breaker 5SY4103-7 reliably protects electrical circuits against overload and short circuit – 1-pole, tripping characteristic C, 3A at 230/400V and 15kA breaking capacity (IEC 60947-2). Suitable for residential, commercial and industrial applications.
Siemens 5SY4108-7 CV - Miniature Circuit Breaker 1-pole C8A 15kA
Number of poles: 1-poleTripping characteristic: CRated current: 8ARated voltage: 230/400VBreaking capacity (IEC 60947-2): 15kAThe Siemens miniature circuit breaker 5SY4108-7 reliably protects electrical circuits against overload and short circuit – 1-pole, tripping characteristic C, 8A at 230/400V and 15kA breaking capacity (IEC 60947-2). Suitable for residential, commercial and industrial applications.
Siemens 5SY4115-7 CV - Miniature Circuit Breaker 1-pole C1.6A 15kA
Number of poles: 1-poleTripping characteristic: CRated current: 1.6ARated voltage: 230/400VBreaking capacity (IEC 60947-2): 15kAThe Siemens miniature circuit breaker 5SY4115-7 reliably protects electrical circuits against overload and short circuit – 1-pole, tripping characteristic C, 1.6A at 230/400V and 15kA breaking capacity (IEC 60947-2). Suitable for residential, commercial and industrial applications.
Siemens 5SY4132-7 CV - Miniature Circuit Breaker 1-pole C32A 15kA
Number of poles: 1-poleTripping characteristic: CRated current: 32ARated voltage: 230/400VBreaking capacity (IEC 60947-2): 15kAThe Siemens miniature circuit breaker 5SY4132-7 reliably protects electrical circuits against overload and short circuit – 1-pole, tripping characteristic C, 32A at 230/400V and 15kA breaking capacity (IEC 60947-2). Suitable for residential, commercial and industrial applications.
Siemens 5SY4108-7 CC - Miniature Circuit Breaker 1-pole C8A 10kA
Number of poles: 1-poleTripping characteristic: CRated current: 8ARated voltage: 230/400VBreaking capacity (EN 60898): 10kAThe Siemens miniature circuit breaker 5SY4108-7 reliably protects electrical circuits against overload and short circuit – 1-pole, tripping characteristic C, 8A at 230/400V and 10kA breaking capacity (EN 60898). Suitable for residential, commercial and industrial applications.
When is a 1-pole miniature circuit breaker with characteristic C used?
1-pole miniature circuit breakers are used in single-phase circuits. In combination with characteristic C, they are particularly suitable for applications with increased inrush currents.
Typical areas of application:
-
Commercial socket circuits
-
Workshop areas
-
Air conditioning units
-
Smaller motors
-
Technical systems with inductive loads
-
IT and server cabinets
If loads cause brief higher current peaks, characteristic C is often the better choice compared to B.
Difference between 1-pole and 1P+N
A 1-pole miniature circuit breaker protects the line conductor only.
A 1P+N miniature circuit breaker, on the other hand, also disconnects the neutral conductor. This can make sense from a safety perspective in certain types of installation.
For classic single-phase circuits, the 1-pole version is often used. The choice depends on the respective system earthing and the installation requirements.
Available rated currents for 1-pole characteristic C
Depending on the connected load and cable cross-section, different rated currents are available.
Frequently chosen variants are:
-
C6
-
C10
-
C13
-
C16
-
C20
-
C25
-
C32
-
C40
The right rated current should always be selected based on the electrical design.
Why characteristic C for single-pole circuits?
Compared to characteristic B, characteristic C allows higher inrush current peaks without unnecessary tripping.
This is particularly relevant for:
-
Devices with transformers
-
Inductive loads
-
Electric tools
-
Systems with short-term load peaks
Characteristic C offers a balanced combination of protection and operational reliability here.
Technical features
1-pole miniature circuit breakers with characteristic C typically offer:
-
Thermal-magnetic tripping
-
Defined tripping curve (5–10 × In)
-
Mounting on DIN rail
-
Standard-compliant design according to DIN EN 60898-1
Installation must be carried out exclusively by a qualified electrician.
Frequently asked questions about 1-pole MCBs with C characteristic
When should you choose a 1-pole MCB with characteristic C?
When loads with increased inrush current are operated in a single-phase circuit, for example motors or technical devices with inductive components.
Is characteristic C permitted in residential buildings?
Basically yes. In residential buildings, however, characteristic B is often used, provided no increased inrush currents occur.
Which rated current is the right one?
The appropriate rated current depends on the cable cross-section and the connected load. Professional planning is absolutely essential.