Miniature Circuit Breakers C20
Miniature circuit breakers C20 (circuit breaker C20 with characteristic C) are designed for circuits with a rated current of 20 amperes and trip at 5 to 10 times the rated current. They are particularly suitable for commercial installations, technical systems and circuits with moderate inrush currents.
In our range you will find Siemens miniature circuit breakers D20 in various pole configurations for professional applications.
Siemens 5SY4320-7 CV - Miniature Circuit Breaker 3-pole C20A 15kA
Number of poles: 3-poleTripping characteristic: CRated current: 20ARated voltage: 400VBreaking capacity (IEC 60947-2): 15kAThe Siemens miniature circuit breaker 5SY4320-7 reliably protects electrical circuits against overload and short circuit – 3-pole, tripping characteristic C, 20A at 400V and 15kA breaking capacity (IEC 60947-2). Suitable for residential, commercial and industrial applications.
Siemens 5SY4120-7 CV - Miniature Circuit Breaker 1-pole C20A 15kA
Number of poles: 1-poleTripping characteristic: CRated current: 20ARated voltage: 230/400VBreaking capacity (IEC 60947-2): 15kAThe Siemens miniature circuit breaker 5SY4120-7 reliably protects electrical circuits against overload and short circuit – 1-pole, tripping characteristic C, 20A at 230/400V and 15kA breaking capacity (IEC 60947-2). Suitable for residential, commercial and industrial applications.
Siemens 5SY4420-7 CV - Miniature Circuit Breaker 4-pole C20A 15kA
Number of poles: 4-poleTripping characteristic: CRated current: 20ARated voltage: 400VBreaking capacity (IEC 60947-2): 15kAThe Siemens miniature circuit breaker 5SY4420-7 reliably protects electrical circuits against overload and short circuit – 4-pole, tripping characteristic C, 20A at 400V and 15kA breaking capacity (IEC 60947-2). Suitable for residential, commercial and industrial applications.
Siemens 5SY4520-7 CV - Miniature Circuit Breaker 1+N-pole C20A 15kA
Number of poles: 1+N-poleTripping characteristic: CRated current: 20ARated voltage: 230/400VBreaking capacity (IEC 60947-2): 15kAThe Siemens miniature circuit breaker 5SY4520-7 reliably protects electrical circuits against overload and short circuit – 1+N-pole, tripping characteristic C, 20A at 230/400V and 15kA breaking capacity (IEC 60947-2). Suitable for residential, commercial and industrial applications.
Siemens 5SY4220-7 CV - Miniature Circuit Breaker 2-pole C20A 15kA
Number of poles: 2-poleTripping characteristic: CRated current: 20ARated voltage: 400VBreaking capacity (IEC 60947-2): 15kAThe Siemens miniature circuit breaker 5SY4220-7 reliably protects electrical circuits against overload and short circuit – 2-pole, tripping characteristic C, 20A at 400V and 15kA breaking capacity (IEC 60947-2). Suitable for residential, commercial and industrial applications.
Siemens 5SY4620-7 CV - Miniature Circuit Breaker 3P+N C20A 15kA
Number of poles: 3P+NTripping characteristic: CRated current: 20ARated voltage: 400VBreaking capacity (IEC 60947-2): 15kAThe Siemens miniature circuit breaker 5SY4620-7 reliably protects electrical circuits against overload and short circuit – 3P+N, tripping characteristic C, 20A at 400V and 15kA breaking capacity (IEC 60947-2). Suitable for residential, commercial and industrial applications.
Siemens 5SY4620-7 CC - Miniature Circuit Breaker 3P+N C20A 10kA
Number of poles: 3P+NTripping characteristic: CRated current: 20ARated voltage: 230/400VBreaking capacity (EN 60898): 10kAThe Siemens miniature circuit breaker 5SY4620-7 reliably protects electrical circuits against overload and short circuit – 3P+N, tripping characteristic C, 20A at 230/400V and 10kA breaking capacity (EN 60898). Suitable for residential, commercial and industrial applications.
When is a miniature circuit breaker C20 used?
C20 MCBs are often used for:
-
commercial socket circuits
-
technical systems
-
smaller machines
-
heating appliances
-
Air conditioning systems
-
motors with moderate starting current
20 amperes is a typical protection for higher-power individual loads.
What does characteristic C mean for C20?
Characteristic C means:
-
instant magnetic tripping at 5–10 × In
-
suitable for moderate inrush current peaks
-
ideal for commercial applications
In comparison:
-
Characteristic B → more sensitive
-
Characteristic D → higher inrush current tolerance
Available versions
Miniature circuit breakers C20 are available as:
-
1-pole
-
1P+N
-
2-pole
-
3-pole
-
3P+N
-
4-pole
Depending on the system type and installation requirement, the suitable version is selected.
Typical commercial applications for miniature circuit breakers C20
C20 is often used for:
-
workshop installations
-
Machines with medium power consumption
-
commercial kitchens
-
Air conditioning systems
-
pump systems
-
technical distribution boards
Especially in the commercial environment, C20 is a frequently used protective device.
Difference between MCBs C16, C20 and C25
Current rating | Typical use |
| C16 | Standard commercial |
| C20 | Higher-power loads |
| C25 | Machines & heavier loads |
C20 bridges the gap between standard commercial and more heavily loaded circuits.
Technical features
A circuit breaker C20 typically offers:
-
Rated current: 20 A
-
Tripping curve: 5–10 × In
-
Thermal-magnetic tripping
-
DIN rail mounting
-
Compliance with DIN EN 60898-1
Installation must be carried out exclusively by a qualified electrician.
Frequently asked questions about MCB C20 (FAQ)
Which applications is C20 suitable for?
For commercial loads with higher power consumption and moderate starting current.
When should a higher current rating be chosen instead of C20?
When the power consumption of the load requires it or the cable dimensioning is designed accordingly.
Is C20 suitable for motors?
Yes, provided the inrush current peaks are within the range of characteristic C.
Is an MCB C20 the same as a circuit breaker C20?
Yes, “circuit breaker C20” is the colloquial term for the miniature circuit breaker C20 with 20A and characteristic C.