Miniature Circuit Breakers D20
Miniature circuit breakers D20 are designed for industrial applications with high inrush currents. With a rated current of 20 amperes and characteristic D, they are particularly suitable for high-power motors, transformers and machines with increased starting current.
In our range you will find Siemens miniature circuit breakers D20 in various pole configurations for professional installations.
Siemens 5SY4120-8 CV - Miniature Circuit Breaker 1-pole D20A 15kA
Number of poles: 1-poleTripping characteristic: DRated current: 20ARated voltage: 230/400VBreaking capacity (IEC 60947-2): 15kAThe Siemens miniature circuit breaker 5SY4120-8 reliably protects electrical circuits against overload and short circuit – 1-pole, tripping characteristic D, 20A at 230/400V and 15kA breaking capacity (IEC 60947-2). Suitable for residential, commercial and industrial applications.
Siemens 5SY4320-8 CV - Miniature Circuit Breaker 3-pole D20A 15kA
Number of poles: 3-poleTripping characteristic: DRated current: 20ARated voltage: 400VBreaking capacity (IEC 60947-2): 15kAThe Siemens miniature circuit breaker 5SY4320-8 reliably protects electrical circuits against overload and short circuit – 3-pole, tripping characteristic D, 20A at 400V and 15kA breaking capacity (IEC 60947-2). Suitable for residential, commercial and industrial applications.
Siemens 5SY4220-8 CV - Miniature Circuit Breaker 2-pole D20A 15kA
Number of poles: 2-poleTripping characteristic: DRated current: 20ARated voltage: 400VBreaking capacity (IEC 60947-2): 15kAThe Siemens miniature circuit breaker 5SY4220-8 reliably protects electrical circuits against overload and short circuit – 2-pole, tripping characteristic D, 20A at 400V and 15kA breaking capacity (IEC 60947-2). Suitable for residential, commercial and industrial applications.
Siemens 5SY4520-8 CV - Miniature Circuit Breaker 1+N-pole D20A 15kA
Number of poles: 1+N-poleTripping characteristic: DRated current: 20ARated voltage: 230/400VBreaking capacity (IEC 60947-2): 15kAThe Siemens miniature circuit breaker 5SY4520-8 reliably protects electrical circuits against overload and short circuit – 1+N-pole, tripping characteristic D, 20A at 230/400V and 15kA breaking capacity (IEC 60947-2). Suitable for residential, commercial and industrial applications.
Siemens 5SY4420-8 CV - Miniature Circuit Breaker 4-pole D20A 15kA
Number of poles: 4-poleTripping characteristic: DRated current: 20ARated voltage: 400VBreaking capacity (IEC 60947-2): 15kAThe Siemens miniature circuit breaker 5SY4420-8 reliably protects electrical circuits against overload and short circuit – 4-pole, tripping characteristic D, 20A at 400V and 15kA breaking capacity (IEC 60947-2). Suitable for residential, commercial and industrial applications.
Siemens 5SY4620-8 CV - Miniature Circuit Breaker 3P+N D20A 15kA
Number of poles: 3P+NTripping characteristic: DRated current: 20ARated voltage: 400VBreaking capacity (IEC 60947-2): 15kAThe Siemens miniature circuit breaker 5SY4620-8 reliably protects electrical circuits against overload and short circuit – 3P+N, tripping characteristic D, 20A at 400V and 15kA breaking capacity (IEC 60947-2). Suitable for residential, commercial and industrial applications.
What does D20 mean?
The designation D20 is made up of:
-
Characteristic D
Magnetic tripping at 10–20 × rated current -
20 amperes rated current
D20 miniature circuit breakers tolerate high current peaks when switched on and prevent unnecessary disconnections with high-power loads.
When is a miniature circuit breaker D20 used?
D20 is often used for:
-
medium-power three-phase motors
-
compressor systems
-
pump systems
-
transformers
-
production and industrial plants
-
technical equipment with increased inrush current
Especially in industrial environments, D20 is a practical and frequently used variant.
Available versions
Miniature circuit breakers D20 are available as:
-
1-pole D20
-
3-pole D20
-
4-pole D20
The suitable number of poles depends on the system type and area of application.
Technical features of D20
Typical properties of D20:
-
Rated current: 20 A
-
Characteristic: D
-
Rated voltage: 230/400 V AC
-
Breaking capacity: 10 kA or 15 kA (depending on model)
-
Standard: DIN EN 60898-1
The selection should be made in accordance with installation regulations and load requirements.
Difference between C20 and D20
The main difference lies in the tripping behaviour:
-
C20
Tripping at 5–10 × rated current
→ suitable for commercial applications -
D20
Tripping at 10–20 × rated current
→ suitable for industrial applications with high starting currents
D20 offers more tolerance for strong inrush current peaks.
Frequently asked questions about miniature circuit breakers D20 (FAQ)
Which applications is D20 suitable for?
For systems with medium to high starting currents, especially in the industrial sector.
Is D20 suitable for residential installations?
As a rule, no. In residential buildings, B or C is usually used.
Is there D20 in 3-pole version?
Yes, especially for three-phase applications 3-pole D20 is widely used.