Skip to main content Skip to search Skip to main navigation
✓ Genuine Siemens products ✓ Shipping within 24h ✓ Purchase on account for existing customers

Miniature Circuit Breakers for Three-Phase Distribution Boards

Three-phase distribution boards (400 V system) reliably supply machines, pumps and technical systems with energy via three line conductors. For protection we rely on Siemens miniature circuit breakers of characteristic C – colloquially also known as circuit breakers –, which are designed for moderate inrush currents and meet the typical requirements of commercial three-phase systems.

In this category you will find miniature circuit breakers of characteristic C in 3-pole, 3P+N and 4-pole versions, suitable for workshops, commercial businesses and technical systems with standard loads.

Filter products

Siemens 5SY4340-7 CV - Miniature Circuit Breaker 3-pole C40A 15kA

Siemens 5SY4340-7 CV - Miniature Circuit Breaker 3-pole C40A 15kA

Number of poles: 3-poleTripping characteristic: CRated current: 40ARated voltage: 400VBreaking capacity (IEC 60947-2): 15kAThe Siemens miniature circuit breaker 5SY4340-7 reliably protects electrical circuits against overload and short circuit – 3-pole, tripping characteristic C, 40A at 400V and 15kA breaking capacity (IEC 60947-2). Suitable for residential, commercial and industrial applications.

Regular price: €51.38
Siemens 5SY4432-7 CV - Miniature Circuit Breaker 4-pole C32A 15kA

Siemens 5SY4432-7 CV - Miniature Circuit Breaker 4-pole C32A 15kA

Number of poles: 4-poleTripping characteristic: CRated current: 32ARated voltage: 400VBreaking capacity (IEC 60947-2): 15kAThe Siemens miniature circuit breaker 5SY4432-7 reliably protects electrical circuits against overload and short circuit – 4-pole, tripping characteristic C, 32A at 400V and 15kA breaking capacity (IEC 60947-2). Suitable for residential, commercial and industrial applications.

Regular price: €34.26
Siemens 5SY4450-7 CV - Leitungsschutzschalter 4-polig C50A 15kA

Siemens 5SY4450-7 CV - Miniature Circuit Breaker 4-pole C50A 15kA

Number of poles: 4-poleTripping characteristic: CRated current: 50ARated voltage: 400VBreaking capacity (IEC 60947-2): 15kAThe Siemens miniature circuit breaker 5SY4450-7 reliably protects electrical circuits against overload and short circuit – 4-pole, tripping characteristic C, 50A at 400V and 15kA breaking capacity (IEC 60947-2). Suitable for residential, commercial and industrial applications.

Regular price: €45.67
Siemens 5SY4463-7 CV - Miniature Circuit Breaker 4-pole C63A 15kA

Siemens 5SY4463-7 CV - Miniature Circuit Breaker 4-pole C63A 15kA

Number of poles: 4-poleTripping characteristic: CRated current: 63ARated voltage: 400VBreaking capacity (IEC 60947-2): 15kAThe Siemens miniature circuit breaker 5SY4463-7 reliably protects electrical circuits against overload and short circuit – 4-pole, tripping characteristic C, 63A at 400V and 15kA breaking capacity (IEC 60947-2). Suitable for residential, commercial and industrial applications.

Regular price: €51.38
Siemens 5SY4425-7 CV - Leitungsschutzschalter 4-polig C25A 15kA

Siemens 5SY4425-7 CV - Miniature Circuit Breaker 4-pole C25A 15kA

Number of poles: 4-poleTripping characteristic: CRated current: 25ARated voltage: 400VBreaking capacity (IEC 60947-2): 15kAThe Siemens miniature circuit breaker 5SY4425-7 reliably protects electrical circuits against overload and short circuit – 4-pole, tripping characteristic C, 25A at 400V and 15kA breaking capacity (IEC 60947-2). Suitable for residential, commercial and industrial applications.

Regular price: €34.26
Siemens 5SY4625-7 CV - Miniature Circuit Breaker 3P+N C25A 15kA

Siemens 5SY4625-7 CV - Miniature Circuit Breaker 3P+N C25A 15kA

Number of poles: 3P+NTripping characteristic: CRated current: 25ARated voltage: 400VBreaking capacity (IEC 60947-2): 15kAThe Siemens miniature circuit breaker 5SY4625-7 reliably protects electrical circuits against overload and short circuit – 3P+N, tripping characteristic C, 25A at 400V and 15kA breaking capacity (IEC 60947-2). Suitable for residential, commercial and industrial applications.

Regular price: €51.38
Siemens 5SY4650-7 CV - Miniature Circuit Breaker 3P+N C50A 15kA

Siemens 5SY4650-7 CV - Miniature Circuit Breaker 3P+N C50A 15kA

Number of poles: 3P+NTripping characteristic: CRated current: 50ARated voltage: 400VBreaking capacity (IEC 60947-2): 15kAThe Siemens miniature circuit breaker 5SY4650-7 reliably protects electrical circuits against overload and short circuit – 3P+N, tripping characteristic C, 50A at 400V and 15kA breaking capacity (IEC 60947-2). Suitable for residential, commercial and industrial applications.

Regular price: €97.06
Siemens 5SY4663-7 CV - Miniature Circuit Breaker 3P+N C63A 15kA

Siemens 5SY4663-7 CV - Miniature Circuit Breaker 3P+N C63A 15kA

Number of poles: 3P+NTripping characteristic: CRated current: 63ARated voltage: 400VBreaking capacity (IEC 60947-2): 15kAThe Siemens miniature circuit breaker 5SY4663-7 reliably protects electrical circuits against overload and short circuit – 3P+N, tripping characteristic C, 63A at 400V and 15kA breaking capacity (IEC 60947-2). Suitable for residential, commercial and industrial applications.

Regular price: €108.47
Siemens 5SY4640-7 CV - Miniature Circuit Breaker 3P+N C40A 15kA

Siemens 5SY4640-7 CV - Miniature Circuit Breaker 3P+N C40A 15kA

Number of poles: 3P+NTripping characteristic: CRated current: 40ARated voltage: 400VBreaking capacity (IEC 60947-2): 15kAThe Siemens miniature circuit breaker 5SY4640-7 reliably protects electrical circuits against overload and short circuit – 3P+N, tripping characteristic C, 40A at 400V and 15kA breaking capacity (IEC 60947-2). Suitable for residential, commercial and industrial applications.

Regular price: €74.22
Siemens 5SY4632-7 CV - Miniature Circuit Breaker 3P+N C32A 15kA

Siemens 5SY4632-7 CV - Miniature Circuit Breaker 3P+N C32A 15kA

Number of poles: 3P+NTripping characteristic: CRated current: 32ARated voltage: 400VBreaking capacity (IEC 60947-2): 15kAThe Siemens miniature circuit breaker 5SY4632-7 reliably protects electrical circuits against overload and short circuit – 3P+N, tripping characteristic C, 32A at 400V and 15kA breaking capacity (IEC 60947-2). Suitable for residential, commercial and industrial applications.

Regular price: €62.80
Siemens 5SY4440-7 CV - Miniature Circuit Breaker 4-pole C40A 15kA

Siemens 5SY4440-7 CV - Miniature Circuit Breaker 4-pole C40A 15kA

Number of poles: 4-poleTripping characteristic: CRated current: 40ARated voltage: 400VBreaking capacity (IEC 60947-2): 15kAThe Siemens miniature circuit breaker 5SY4440-7 reliably protects electrical circuits against overload and short circuit – 4-pole, tripping characteristic C, 40A at 400V and 15kA breaking capacity (IEC 60947-2). Suitable for residential, commercial and industrial applications.

Regular price: €51.38
Siemens 5SY4325-7 CV - Miniature Circuit Breaker 3-pole C25A 15kA

Siemens 5SY4325-7 CV - Miniature Circuit Breaker 3-pole C25A 15kA

Number of poles: 3-poleTripping characteristic: CRated current: 25ARated voltage: 400VBreaking capacity (IEC 60947-2): 15kAThe Siemens miniature circuit breaker 5SY4325-7 reliably protects electrical circuits against overload and short circuit – 3-pole, tripping characteristic C, 25A at 400V and 15kA breaking capacity (IEC 60947-2). Suitable for residential, commercial and industrial applications.

Regular price: €22.84

What is a three-phase distribution board?

A three-phase distribution board supplies systems with power via three line conductors (L1, L2, L3) and optionally a neutral conductor. Compared with single-phase supply, three-phase power offers higher power transmission, more even load distribution and more efficient operation — which is why it is standard in workshops, production halls and commercial systems.

Which miniature circuit breakers are used in three-phase distribution boards?

In three-phase systems, the following versions are predominantly used:

3-pole miniature circuit breakers

Protection of all three phases without neutral conductor.

3P+N miniature circuit breakers

Additional disconnection of the neutral conductor.

4-pole miniature circuit breakers

Complete isolation of all active conductors.

These pole configurations are particularly relevant for industrial distribution boards and machine connections.

When is characteristic C suitable?

Characteristic C trips at 5 to 10 times the rated current and is therefore ideal for loads with moderate inrush currents:

  • Pumps and air-conditioning systems

  • Machine tools in the commercial sector

  • Lighting systems with inductive ballasts

  • mixed commercial loads

For motors, transformers and systems with significantly higher inrush currents, characteristic D is the more suitable choice (see Industrial sub-distribution boards)

Depending on current ratings in three-phase distribution boards

Depending on power demand, different rated currents are used:

Current rating

Typical use

C16-C20

smaller commercial loads

C25

standard machines, workshop systems

C32

heavier loads, larger three-phase distribution boards

C40

high-load applications in commercial settings

The choice depends on:

  • Power consumption

  • cable dimensioning

  • System type

  • Inrush current behavior

Applications for three-phase circuit breakers

  • production machines

  • compressors

  • pump systems

  • conveyor technology

  • Industrial furnaces

  • Workshop distribution boards

  • Commercial sub-distribution boards

Properly rated three-phase protection safeguards both cables and connected equipment.

Technical requirements in three-phase distribution boards

Circuit breakers for three-phase distribution boards must comply with DIN EN 60898-1, have a suitable short-circuit breaking capacity, trip thermally-magnetically and be suitable for DIN rail mounting. Installation may only be carried out by a qualified electrician.

Related categories

3-pole miniature circuit breakers

4-pole miniature circuit breakers

Characteristic C

Characteristic D

C32

D32

FAQ

Is characteristic C sufficient for my three-phase system?

With moderate starting currents (pumps, HVAC, general commercial loads), yes. For motors with high inrush current peaks, characteristic D is recommended.

Which pole configuration do I need?

3-pole for pure phase protection, 3P+N if the neutral conductor is to be switched too, 4-pole for complete disconnection of all conductors including the neutral.

Which current rating suits my system?

That depends on power consumption and cable sizing — as a guide, C25 and C32 are the most widespread in commercial installations.