Miniature Circuit Breakers C16
C16 circuit breakers (C16 miniature circuit breakers) with characteristic C are designed for circuits with a rated current of 16 amperes. They are predominantly used in commercial and technical installations where consumers with moderate inrush currents need to be protected.
With magnetic tripping at 5–10 × In, C16 circuit breakers are suited to applications with moderate inrush current peaks, as occur with small motors, air conditioners or technical systems. According to our own demand analysis, C16 is one of the most requested current ratings of characteristic C.
Here you will find Siemens C16 circuit breakers in various pole configurations for professional installations.
Siemens 5SY4316-7 CV - Miniature Circuit Breaker 3-pole C16A 15kA
Number of poles: 3-poleTripping characteristic: CRated current: 16ARated voltage: 400VBreaking capacity (IEC 60947-2): 15kAThe Siemens miniature circuit breaker 5SY4316-7 reliably protects electrical circuits against overload and short circuit – 3-pole, tripping characteristic C, 16A at 400V and 15kA breaking capacity (IEC 60947-2). Suitable for residential, commercial and industrial applications.
Siemens 5SY4116-7 CV - Miniature Circuit Breaker 1-pole C16A 15kA
Number of poles: 1-poleTripping characteristic: CRated current: 16ARated voltage: 230/400VBreaking capacity (IEC 60947-2): 15kAThe Siemens miniature circuit breaker 5SY4116-7 reliably protects electrical circuits against overload and short circuit – 1-pole, tripping characteristic C, 16A at 230/400V and 15kA breaking capacity (IEC 60947-2). Suitable for residential, commercial and industrial applications.
Siemens 5SY4316-7 CC - Miniature Circuit Breaker 3-pole C16A 10kA
Number of poles: 3-poleTripping characteristic: CRated current: 16ARated voltage: 400VBreaking capacity (EN 60898): 10kAThe Siemens miniature circuit breaker 5SY4316-7 reliably protects electrical circuits against overload and short circuit – 3-pole, tripping characteristic C, 16A at 400V and 10kA breaking capacity (EN 60898). Suitable for residential, commercial and industrial applications.
Siemens 5SY4416-7 CV - Miniature Circuit Breaker 4-pole C16A 15kA
Number of poles: 4-poleTripping characteristic: CRated current: 16ARated voltage: 400VBreaking capacity (IEC 60947-2): 15kAThe Siemens miniature circuit breaker 5SY4416-7 reliably protects electrical circuits against overload and short circuit – 4-pole, tripping characteristic C, 16A at 400V and 15kA breaking capacity (IEC 60947-2). Suitable for residential, commercial and industrial applications.
Siemens 5SY4516-7 CV - Miniature Circuit Breaker 1+N-pole C16A 15kA
Number of poles: 1+N-poleTripping characteristic: CRated current: 16ARated voltage: 230/400VBreaking capacity (IEC 60947-2): 15kAThe Siemens miniature circuit breaker 5SY4516-7 reliably protects electrical circuits against overload and short circuit – 1+N-pole, tripping characteristic C, 16A at 230/400V and 15kA breaking capacity (IEC 60947-2). Suitable for residential, commercial and industrial applications.
Siemens 5SY4215-7 CC - Miniature Circuit Breaker 2-pole C1.6A 10kA
Number of poles: 2-poleTripping characteristic: CRated current: 1.6ARated voltage: 230/400VBreaking capacity (EN 60898): 10kAThe Siemens miniature circuit breaker 5SY4215-7 reliably protects electrical circuits against overload and short circuit – 2-pole, tripping characteristic C, 1.6A at 230/400V and 10kA breaking capacity (EN 60898). Suitable for residential, commercial and industrial applications.
Siemens 5SY4616-7 CV - Miniature Circuit Breaker 3P+N C16A 15kA
Number of poles: 3P+NTripping characteristic: CRated current: 16ARated voltage: 400VBreaking capacity (IEC 60947-2): 15kAThe Siemens miniature circuit breaker 5SY4616-7 reliably protects electrical circuits against overload and short circuit – 3P+N, tripping characteristic C, 16A at 400V and 15kA breaking capacity (IEC 60947-2). Suitable for residential, commercial and industrial applications.
Siemens 5SY4216-7 CV - Miniature Circuit Breaker 2-pole C16A 15kA
Number of poles: 2-poleTripping characteristic: CRated current: 16ARated voltage: 400VBreaking capacity (IEC 60947-2): 15kAThe Siemens miniature circuit breaker 5SY4216-7 reliably protects electrical circuits against overload and short circuit – 2-pole, tripping characteristic C, 16A at 400V and 15kA breaking capacity (IEC 60947-2). Suitable for residential, commercial and industrial applications.
When is a miniature circuit breaker C16 used?
C16 is typically used for:
- commercial installations
- workshops
- air-conditioning systems
- small electric motors
- pumps
- lighting systems with ballasts
- IT and server technology
16 amperes is one of the most requested ratings of characteristic C and a common protective rating for commercial circuits with moderate inrush currents.
Meaning of characteristic C at 16A
Characteristic C means:
- instantaneous magnetic tripping at 5–10 × In
- suitable for moderate inrush current peaks
- robust protection in commercial settings
In comparison:
- Characteristic B → more sensitive, more suited to residential use
- Characteristic D → higher inrush current tolerance for powerful motors
C16 is often chosen when moderate inrush currents need to be protected but no industrial high-performance level is required, as is the case with characteristic D.
Available pole configurations for C16
C16 circuit breakers are available as:
- 1-pole
- 1P+N
- 2-pole
- 3-pole
- 3P+N
- 4-pole
In commercial settings, 3-pole and 4-pole variants are particularly relevant, as they are used in three-phase systems.
Typical applications for C16 circuit breakers
- commercial sub-distribution boards
- workshop installations
- small compressors
- air-conditioning systems
- lighting systems with ballasts
- IT and server technology
Particularly in commercial circuits with moderate inrush currents, C16 is a frequently used protective device.
Difference between C13, C16 and D16 circuit breakers
- C13 → moderate inrush currents, smaller commercial consumers
- C16 → standard value for commercial circuits, one of the most requested current ratings
- D16 → significantly higher inrush current tolerance for motors and industrial applications at the same current rating
C16 is ideal for moderate continuous load in commercial settings, whereas D16 only becomes necessary at significantly higher inrush current peaks.
Technical features of C16
Typical properties:
- Rated current: 16 A
- Tripping characteristic: 5–10 × In
- thermal-magnetic tripping
- DIN rail mounting
- Compliance with DIN EN 60898-1
- high short-circuit breaking capacity
Installation may only be carried out by an electrician.
Frequently asked questions about MCB C16 (FAQ)
Which systems is C16 suitable for?
For commercial consumers and technical systems with moderate inrush currents, e.g. air conditioners or small motors.
When should characteristic D be chosen instead of C16?
When significantly higher inrush current peaks occur, for example with motors with high starting current.
Is C16 suitable for three-phase?
Yes, particularly in 3-pole or 4-pole versions.
Is a C16 circuit breaker also known as a C16 miniature circuit breaker?
Yes, the C16 miniature circuit breaker is the colloquial name for the C16 circuit breaker with 16A and characteristic C.